The following clauses are intended to specify the mapping relationship between HAIM and OMA DWAPI with tables.

OMA Device Web Application Programming Interface (DWAPI)) [7] is based on OMA Generic Open Terminal Application Programming Interface (GotAPI) [19] and supports Personal Healthcare Devices (DWAPI-PCH) and 3D printer (DWAPI-3DP).

OMA DWAPI has no concept that corresponds to ModuleClass in oneM2M. The mappings of DataPoints to data objects of OMA DWAPI are expressed in following clauses.

7.1.2 Device Models

7.1.2.1 device3Dprinter

The device3DPrinter of HAIM shall be mapped to 3D printer of OMA DWAPI-3DP on the basis of Table 7.1.2.1-1.

Table 7.1.2.1-1: Map of device3Dprinter of oneM2M HAIM to OMA DWAPI-3DP

ModuleClass Data Points of oneM2M HAIM data objects of OMA DWAPI-3DP Description
binarySwitch powerState - See clause 5.3.1.12.
The powerState is not supported in OMA DWAPI-3DP data object. The power state is assumed power-on in OMA DWAPI-3DP.
faultDetection code operatingStatus See clause 5.3.1.34.
It shall be the integer type at HAIM, but shall be the string type at OMA DWAPI-3DP. See the Table 7.1.2-2 .
threeDprinter printType printType See clause 5.3.1.1.
threeDprinter printSizeX printSizeX See clause 5.3.1.1.
threeDprinter printSizeY printSizeY See clause 5.3.1.1.
threeDprinter printSizeZ printSizeZ See clause 5.3.1.1.
threeDprinter network network See clause 5.3.1.1.
threeDprinter memorySize memorySize See clause 5.3.1.1.
runState currentMachineState operatingStatus See clause 5.3.1.75.
This value represents the machineState of the 3D printer itself. This value SHALL be interpreted by using hd:enumMachineState and generated operatingStatus as a string.
See the Table 7.1.2-2 .
temperature currentTemperature nozzleTemp See clause 5.3.1.87.
This value represents the temperature of the nozzle. This value SHALL be a float number in a range from 0,0 to 1 000,0.
The unit is C.
printQueue uri uri See clause 5.3.1.67.
printQueue printingState msg See clause 5.3.1.67.
This value represents the machineState of the queued printing job. This value shall be interpreted by using hd:enumMachineState and generated msg as a string.
See the Table 7.1.2-3.

Table 7.1.2.1-2: Map of hd:enumMachineState of oneM2M HAIM to operatingStatus of OMA DWAPI-3DP

Value Interpretation operatingStatus of OMA DWAPI-3DP Note
1 idle RDY Ready to use
2 preActive Not available
3 active RUN Under printing operation
4 reserved Not available
5 stopped Not available
6 error MAN Maintenance needed
7 diagnostic Not available
8 test Not available
9 maintenance MAN Maintenance needed
10 clear CLR Printing completed but the result is not removed yet
11 charging Not available

Table 7.1.2-1-3: Map of hd:enumJobState of oneM2M HAIM to msg of OMA DWAPI-3DP

Value Interpretation msg of OMA DWAPI-3DP Note
1 aborted Not available
2 cancelled Not available
3 completed Completed
4 paused Waiting
5 pending Waiting
6 processing Good Start

7.1.2.2 deviceBloodPressureMonitor

DeviceBloodPressureMonitor of HAIM shall be mapped to Blood Pressure Monitor of OMA DWAPI-PCH on the basis of Table 7.1.2.2-1.

Table 7.1.2-2-1: Map of deviceBloodPressureMonitor of oneM2M HAIM to OMA DWAPI-PCH

ModuleClass DataPoints of oneM2M HAIM data objects of OMA DWAPI-PCH Description
sphygmomanometer diastolicPressure diastolic See clause 5.3.1.83.
sphygmomanometer systolicPressure systolic See clause 5.3.1.83.
sphygmomanometer meanPressure mean See clause 5.3.1.83.
pulsemeter pulseRate pulse See clause 5.3.1.68.
battery level batteryLevel See clause 5.3.1.10.
It shall be the integer type at HAIM, but shall be the float type at OMA DWAPI-PCH.
It shall be the rounded percentage of the current level of battery in the range of [0, 100] at HAIM, but shall be a float number in the range of [0,0, 1,0] atOMA DWAPI-PCH.

7.1.2.3 deviceGlucosemeter

DeviceGlucometer of HAIM shall be mapped to Glucometer of OMA DWAPI-PCH on the basis of Table 7.1.2.3-1.

Table 7.1.2.3-1: Map of deviceGlucometer of oneM2M HAIM to OMA DWAPI-PCH

ModuleClass DataPoints of oneM2M HAIM data objects of OMA DWAPI-PCH Description
glucometer concentration concentration See clause 5.3.1.42.
glucometer hba1c hba1c See clause 5.3.1.42.
glucometer contextExercise contextExercise See clause 5.3.1.42.
glucometer contextMedication contextMedication See clause 5.3.1.42.
glucometer contextCarbohydratesAmount contextCarbohydrates See clause 5.3.1.42.
glucometer contextCarbohydratesSource contextCarbohydrates See clause 5.3.1.42.
glucometer contextMeal contextMeal See clause 5.3.1.42.
glucometer contextLocation contextLocation See clause 5.3.1.42.
glucometer contextTester contextTester See clause 5.3.1.42.
glucometer contextHealth contextHealth See clause 5.3.1.42.
battery level batteryLevel See clause 5.3.1.10.
It shall be the integer type at HAIM, but shall be the float type at OMA DWAPI-PCH.
It shall be the rounded percentage of the current level of battery in the range of [0, 100] at HAIM, but shall be a float number in the range of [0,0, 1,0] atOMA DWAPI-PCH.

7.1.2.4 devicePulseOximeter

DevicePulseOximeter of HAIM shall be mapped to Pulse Oximeter of OMA DWAPI-PCH on the basis of Table 7.1.2.4-1.

Table 7.1.2.4-1: Map of devicePulseOximeter of oneM2M HAIM to OMA DWAPI-PCH

ModuleClass DataPoints of oneM2M HAIM data objects of OMA DWAPI-PCH Description
pulsemeter modality spo2, pulse See clause 5.3.1.68.
When "oximeter" module does not exist, "pulsemeter" module is mandatory.
oximeter modality spo2, pulse See clause 5.3.1.59.
When "pulsemeter" module does not exist, ""oximeter" module is mandatory.
battery level batteryLevel See clause 5.3.1.10.
It shall be the integer type at HAIM, but shall be the float type at OMA DWAPI-PCH.
It shall be the rounded percentage of the current level of battery in the range of [0, 100] at HAIM, but shall be a float number in the range of [0,0, 1,0] atOMA DWAPI-PCH.

7.1.2.5 deviceThermometer

DeviceTermometer of HAIM shall be mapped to Thermometer of OMA DWAPI-PCH on the basis of Table 7.1.2.5-1.

Table 7.1.2.5-1: Map of deviceThermometer of oneM2M HAIM to OMA DWAPI-PCH

ModuleClass Data Points of oneM2M HAIM data objects of OMA DWAPI-PCH Description
temperature unit temperature See clause 5.3.1.87.
battery level batteryLevel See clause 5.3.1.10.
It shall be the integer type at HAIM, but shall be the float type at OMA DWAPI-PCH.
It shall be the rounded percentage of the current level of battery in the range of [0, 100] at HAIM, but shall be a float number in the range of [0,0, 1,0] atOMA DWAPI-PCH.

7.1.2.6 deviceWeightScaleAndBodyCompositionAnalyser

DeviceWeightScaleAdBodyCompositionAnalyser of HAIM shall be mapped to Weight Scale Body Composition Analyser of OMA DWAPI-PCH on the basis of Table .

Table 7.1.2.6-1: Map of deviceWeightScaleAdBodyCompositionAnalyser of oneM2M HAIM to OMA DWAPI-PCH

ModuleClass DataPoints of oneM2M HAIM data objects of OMA DWAPI-PCH Description
bodyCompositionAnalyser bodyLength bodyLength See clause 5.3.1.14.
bodyCompositionAnalyser Bmi bmi See clause 5.3.1.14.
bodyCompositionAnalyser fatFreeMass fatFreeMass See clause 5.3.1.14.
bodyCompositionAnalyser softLeanMass softLeanMass See clause 5.3.1.14.
bodyCompositionAnalyser muscleMass muscleMass See clause 5.3.1.14.
bodyCompositionAnalyser basalMetabolism basalMetabolism See clause 5.3.1.14.
bodyCompositionAnalyser impedance impedance See clause 5.3.1.14.
weight weight bodyMass See clause 5.3.1.99.
bioElectricalImpedanceAnalysis water bodyWater See clause 5.3.1.13.
bioElectricalImpedanceAnalysis fat bodyFat See clause 5.3.1.13.
bioElectricalImpedanceAnalysis muscle musclePercentage See clause 5.3.1.13.
battery level batteryLevel See clause 5.3.1.10.
It shall be the integer type at HAIM, but shall be the float type at OMA DWAPI-PCH.
It shall be the rounded percentage of the current level of battery in the range of [0, 100] at HAIM, but shall be a float number in the range of [0,0, 1,0] at OMA DWAPI-PCH.

7.1.2.7 deviceHeartRateMonitor

DeviceHeartRateMonitor of HAIM shall be mapped to Heart Rate Monitor of OMA DWAPI-PCH on the basis of Table 7.1.2.7-1.

Table 7.1.2.7-1: Map of deviceHeartRateMonitor of oneM2M HAIM to OMA DWAPI-PCH

ModuleClass DataPoints of oneM2M HAIM data objects of OMA DWAPI-PCH Description
pulsemeter pulseRate rate See clause 5.3.1.68.
pulsemeter rr rr See clause 5.3.1.68.
pulsemeter energy energy See clause 5.3.1.68.
battery level batteryLevel See clause 5.3.1.10.
It shall be the integer type at HAIM, but shall be the float type at OMA DWAPI-PCH.
It shall be the rounded percentage of the current level of battery in the range of [0, 100] at HAIM, but shall be a float number in the range of [0,0, 1,0] atOMA DWAPI-PCH.

7.1.3 Data Types

Data types of oneM2M HAIM and OMA DWAPI-PCH shall be mapped each other on the basis of Table 7.1.3-1.

Table 7.1.3-1: Map of data types between oneM2M and OMA DWAPI-PCH

oneM2M data type Mapping to data type in OMA DWAPI Description
xs:integer int, number, string Data type for 32-bit signed integer.

For indicating 3D printerState, the integer value should be interpreted into string by referring the tables in clause 7.1.2.1 .
xs:string string, array Data type for text. The length limitation should be considered for the mapping.
xs:float float Data type for a single precision 32-bit floating point type as defined in XML Schema 1.0 [14] as the float primitive type.
xs:boolean boolean Data type for Boolean.