5.3 Constrained actuator as ADN
5.3.1 Profile description
The profile defines constraint actuator that is powered by battery and intended to be used fro years after deployment without any human interference for maintenance. Therefore, the function of constraint actuator need to be very limited.
An actuator is intended to be receiving control command from CSE via notification or other means. The actuator then actuates according to the control command.
The actuator need to receive control command. As a result, the actuator need to be request reachable to receive notification or be able to start a polling channel.
5.3.2 Profile usage examples
Swithes deployed along the street light to switch on or off the street light remotely.
5.3.3 Fundamental feature sets
Table 5.3.3-1: Fundamental feature sets for constrained sensor as ADN
| Function | Feature Set | Feature | Remark |
|---|---|---|---|
| GEN | AE/GEN/00001 | At least one | Resource identifiers |
| GEN | AE/GEN/00002 | AE/GEN/00002/00001 | Support Create request targeting one resource |
| REG | AE/REG/00002 | AE/REG/00002/00001 | Create <AE> with mandatory attributes[2] |
| REG | AE/REG/00002 | AE/REG/00002/00003 | Create <AE> with pointOfAccess |
| SUB | AE/SUB/00001 | AE/SUB/00001/00001 | Create <subscription> with mandatory attributes [2] |
5.3.4 ADN1-requestReachable
Table 5.3.4-1: Notification feature sets for constrained actuator as ADN
| Function | Feature Set | Feature | Remark |
|---|---|---|---|
| SUB | AE/SUB/00004 | AE/SUB/00004/00001 | Receiving a notification |
5.3.5 ADN1- pollingChannel
Table 5.3.5-1: Polling Channel feature sets for constrained actuator as ADN
| Function | Feature Set | Feature | Remark |
|---|---|---|---|
| PCH | GE/PCH/00001 | GE/PCH/00001/00001 GE/PCH/00001/00002 GE/PCH/00001/00003 |
Polling Channel resource management |
| PCH | GE/PCH/00002 | GE/PCH/00002/00001 | Long Polling Procedure |